Case Study

Medical Waste Incinerator CO Removal — Field Test

Field test of CO oxidation catalyst performance on a medical waste pyrolysis / incineration exhaust stream.

Reported field test result — test date 2023-03-20

CO: 11,224.2 mg/Nm³ → 16.2 mg/Nm³

Reported result

The original field test record reports CO concentration reduced from 11,224.2 mg/Nm³ to 16.2 mg/Nm³ on 2023-03-20.

Data completeness note

For full engineering evaluation, the following data should be attached to the original record:

  • Gas flow rate
  • Operating temperature
  • Oxygen content
  • Continuous operating time
  • Detection method and instrument

What this case demonstrates

The test shows high CO conversion on a fluctuating incineration stream — evidence of the catalyst’s tolerance to thermal cycling and multi-pollutant conditions.

Engineering takeaways

The reported field data — CO reduced from 11,224.2 mg/Nm³ to 16.2 mg/Nm³ on 2023-03-20 — was measured on a medical waste incinerator, a stream that also carries HCl, SO₂, heavy metals and moisture. Catalyst survival in this duty depends on the upstream gas cleaning: the acid and particulate removal stages protect the catalyst from rapid poisoning and blinding.

For a permanent installation, the follow-up questions are the operating temperature at the catalyst position, the CO spike behaviour during batch charging, and the expected chloride exposure — all of which set the deactivation margin in the sizing calculation.